Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

Shenzhen Liruisi Electronics Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility from wholesalers
     
    Buy cheap Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility from wholesalers
    • Buy cheap Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility from wholesalers
    • Buy cheap Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility from wholesalers
    • Buy cheap Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility from wholesalers
    • Buy cheap Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility from wholesalers

    Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

    Ask Lasest Price
    Brand Name : lpsrits
    Price : bargaining
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Delivery Time : 8 working days
    • Product Details
    • Company Profile

    Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

    Single Row Scheme Of Micro Module Data Center Energy Saving And Capacity Expansion Compatibility

    Advantages and characteristics


    VMDC-06-RRS
    cabenit: 1*Integrated cabinet+ 1*IT cabenit

    UPS: 6kVA rack-mounted
    cooling: 5.6kW InRow air-conditioner

    Redundancy:N


    Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

    VMDC-10-RRS
    cabenit 1*Integrated cabinet+ 2*ITcabenit

    UPS: 10+10(kVA)rack-mounted

    cooling: 7.6+7.6kWInRow air-conditioner

    Redundancy: N+1


    Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

    VMDC-20-RRS
    cabenit: 1*Integrated cabinet+ 4*ITcabenit

    UPS: 20+20(kVA)rack-mounted

    cooling: 17.6+17.6kW InRow air-conditioner

    Redundancy: N+1


    Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

    VMDC-30-RRS
    cabenit: 1*Integrated cabinet+ 6*ITcabenit

    UPS: 30+30(kVA)rack-mounted

    cooling: 25.1+25.1kW InRow air-conditione

    Redundancy: N+1


    Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

    VMDC-40-RRS
    cabenit: 1*Integrated cabinet+ 9*ITcabenit

    UPS: 40+10(kVA)modular
    cooling: 21.2*(2+1)kW
    Redundancy: N+1


    Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility


    Technical

    monitoring system

    modelVMDC-06-RRSVMDC-10-RRSVMDC-20-RRSVMDC-30-RRSVMDC-40-RRSODM
    cabenit quanity235710LESS THAN 20
    ITcabenit quanity23469LESS THAN 20
    POWER DENITISY -kW/CAbinet22444less than15kW/CABINET
    Redundancy styleNN+1N+1N+1N+1N/N+1/2N
    depth -mm14001400140014001400customization
    length -mm15002400360057006900customization
    height -mm20002000200020002000less than 2500
    POWER SYSTEM
    UPSCAPACITY -kVA610+1020+2030+3040+10MAX90kVA
    UPSrack-mountedrack-mountedrack-mountedrack-mountedmodularrack-mountedmodular
    )battery configuration(1 h)12V/40Ah 16Pcs12V/65Ah 16Pcs12V/65Ah 40Pcs12V/100Ah 40Pcs12V/150Ah 40Pcscustomization
    PDU32A basic 16 port32A basic 16 port32A basic 16 port32A basic 16 port32A basic 16 portcustomization
    Total input power specification

    63A/1P/220V

    /50Hz/60Hz

    63A/3P/380V

    /50Hz/60Hz

    80A/3P/380V

    /50Hz/60Hz

    125A/3P/380V

    /50Hz/60Hz

    160A/3P/380V

    /50Hz/60Hz

    customization
    cooling system
    cooling styleAir coolingAir coolingAir coolingAir coolingAir coolingAir cooling, water cooling and chilled water
    air-conditioner configuration-kW5.67.6+7.617.6+17.625.1+25.121.2*(2+1)Per Situation
    air-conditioner sytleInRowInRowInRowInRowInRowRow / rack / top mounted
    Emergency ventilationAutomatic door openingAutomatic door openingAutomatic door openingAutomatic door openingAutomatic door openingAutomatic door opening
    monitoring sysem
    monitoringTouch screenTouch screenTouch screenTouch screenTouch screenOptional video, access control, audible and visual / SMS alarm, centralized monitoring, etc
    Temperature and humidityTemperature and humidityTemperature and humidityTemperature and humidityTemperature and humidity
    UPS managementUPS managementUPS managementUPS managementUPS management
    air-conditioner managementair-conditioner managementair-conditioner managementair-conditioner managementair-conditioner management
    smoke detectionsmoke detectionsmoke detectionsmoke detectionsmoke detection
    water leakagewater leakagewater leakagewater leakagewater leakage漏水
    Door opening statusDoor opening statusDoor opening statusDoor opening statusDoor opening status

    The single row scheme of micro module data center fully considers the standardized design, energy saving and capacity expansion compatibility, and adopts standardized power supply, refrigeration and cabinet units to help it experts seamlessly plan, expand and manage these key infrastructure of data center for the future.